Note that all Eowave sensors are ready to use, include filtering or amplifying circuitry (when needed) and are calibrated for maximum bandwidth. They are delivered with a 2 meters-long cable with a jack TRS connector (Eobody1, 2 & 3 compatible) or a 3 pin connector (Eobody2 HF or OEM board compatible). No soldering is required. All Eowave sensors are made on demand. If you have special request, please, contact eowave.
Trigger sound, video, lights... On/Off sensors are used to trigger events.
They emit only 2 values (0 and 127 in MIDI).
Note that depending on manufacturers, sensors appearence may be subjet to change without notice.
Sensors technical comparison table
Sensor type
Number of outputs
Continuous/
on/off
Active /passive
Need ext.
power
Integrated
additionnal
circuitry
Editor parameters setting
2D GForce
2
Continuous
active
no
yes
Plug&play
3D GForce
3
Continuous
active
no
yes
Plug&play
IR
1
Continuous
active
yes
yes
- the output signal can be amplified by setting the analogue zoom on 1
- To reduce IR noise, filter the signal in the editor by setting a high filter value.
Light
1
Continuous
passive
no
yes
Plug&play
movement
1
On/off
passive
no
yes
Plug&play
detection
1
On/off
active
yes
A gate value of 11 will reduce noise to avoid uncontrolled triggering.
flexion
1
Continuous
active
no
Yes
External trimmer
Plug&play. Sensitivity can be set with the external trimmer.
footswitch
1
On/off
passive
no
yes
Plug&play
A gate value of 11 will reduce noise to avoid uncontrolled triggering.
joystick
2
Continuous
passive
no
yes
- Plug&play
Expression pedal
1
Continuous
passive
no
no
- Plug&play
- Note that you can use the inverse feature.
- the linear response of a pedal can be changed to a logarithmic or exponential response with the curve parameter.
position
1
Continuous
passive
no
yes
Plug&play
pressure
1
Continuous
passive
no
yes
Plug&play
potentiometer
1
Continuous
passive
no
no
Plug&play
Shock piezzo
1
On/off
active
no
Yes
amplifier
Use a sensorbox with trigger inputs, which are sensitive to the velocity.
A gate value of 11 will reduce noise to avoid uncontrolled triggering.
switch
1
On/off
passive
no
no
Plug&play
A gate value of 11 reduce will noise to avoid uncontrolled triggering.
temperature
1
Continuous
passive
no
no
Plug&play
ultrasonic
1
Continuous
active
yes
yes
Note that when using more than one, they need to be synchronized. (Only with digital I/O).
Gyroscope 2 axis
2
Continuous
active
no
yes
Plug&play
Gyroscope 5 axis
5
Continuous
active
no
yes
Plug&play
sonometer
1
Continuous
active
no
yes
Plug&play
If you have any questions about our products, feel free to contact us and we'll come back to you as soon as possible!